Skip to main content
Sydney Waterproofing NSW

NSW contractor licence 260823C

Negative-side waterproofing in Sydney

When the outside of a below-ground wall can’t be reached, we waterproof it from the inside with a system that holds against water pressing from behind.

LICENSED WATERPROOFER ● NSW 260823C ● SINCE 2013 ●Finished look
  • Active leaks stopped first
  • Treated from the inside face
  • Joints and corners detailed

Get a free quote

Negative-side waterproofing

Add photos if you can. We usually reply within one business day.

NSW contractor licence 260823C

Optional, up to 5 photos0/5 photos added

Our service

What negative-side work includes

  • Stopping active leaks

    Running water at joints and cracks is stopped first, with injection or a fast-setting plug, so the coating isn’t washed off while it cures.

  • Opening up the surface

    Grinding or scabbling back to clean, open concrete so the system can bond into it.

  • Joints and corners

    The wall-to-floor junction and construction joints are cut out and filled before the coats go on.

  • Coats and curing

    Applied to a damp surface where the product calls for it, and kept moist while it cures.

Signs

When negative-side is the right choice

Not sure? Send photos for a quote
  1. The outside is buried or built over

    Excavating isn’t possible, or would cost more than the room is worth.

  2. The wall is concrete or solid masonry

    These systems need a sound, cement-based surface to bond into; they don’t go onto plasterboard, painted render or timber.

  3. The cracks are stable

    Hairline shrinkage cracks can be sealed. Cracks that open and close with the seasons need injection or structural advice first.

  4. Old coatings can come off

    Paint, render and earlier coatings are removed so the new system bonds to the concrete itself.

The build-up

Through the wall, from soil to room

A negative-side treatment on an existing concrete basement wall.

Diagram: Soil and groundwater, Concrete wall, Repaired cracks and joints, Crystalline or cementitious base coat, Second coat, Render or topping, from the bottom up, separated to show the order they go down123456
  1. Protects the coats and takes the finish inside the room.

  2. Builds the system to its full thickness.

  3. Bonds into the opened-up concrete surface.

  4. Injected, or cut out and filled, before coating.

  5. Water moves into its pores, joints and cracks.

  6. Pressing on the outside face, which can’t be reached.

Diagram of a typical job, not to scale. Select a layer to see what it does.

Step by step

How the job runs

  1. 1

    Photos of the leak

    Photos of where water shows and whether it runs, seeps or only stains, for a free written quote. We usually reply within one business day.

  2. 2

    Active leaks stopped

    Running water at joints and cracks is stopped first, with injection or a fast-setting plug.

  3. 3

    Surface opened up

    The concrete is ground back to a clean, open surface, and the wall-to-floor junction and joints are cut out and filled.

  4. 4

    Coats, kept moist

    Crystalline or cementitious coats go on, applied damp where the product calls for it and kept moist while they cure.

Prices

How we price negative-side waterproofing

Negative-side work is priced on the wall area, the cracks and joints to repair and the old coatings to come off, so we price it from photos or a visit. Quotes are free.

What moves the price: our cost guide
LICENSED WATERPROOFER ● NSW 260823C ● SINCE 2013 ●

Why choose us

Licensed, insured and backed in writing

A licensed waterproofer who does the job once and does it properly, with the insurance, paperwork and warranty to back it.

Check licence 260823C on the NSW register
  • Licence 260823C

    NSW Waterproofing Technician since 2013, current to 10 July 2028.

  • $20m insured

    Public liability cover on every job, big or small.

  • Statutory warranties

    On home building work in NSW: six years for major defects, two for others.

  • Tested before it’s covered

    Showers, bathrooms, balconies and flat roofs flood tested, with a waterproofing certificate.

Before you book

Details and questions

Still not sure?

Send a few photos of the job and the answer comes back with your free written quote.

Send photos for a quoteCall 0451 662 300

More about this work

The positive side of a wall is the side the water comes from; the negative side is the side you’re keeping dry. Waterproofing from the positive side is better, but it isn’t always possible. On an existing basement, a wall built hard against the boundary or a lift pit under a building, the outside is under soil, a neighbour’s footing or another slab.

A negative-side system has to bond into the wall well enough to resist water pushing it off from behind. That rules out most membranes made for showers and balconies, which rely on water landing on top of them. Cementitious and crystalline systems are used instead; crystalline products react with moisture in the concrete and form crystals in its pores and fine cracks.

The trade-off is that the wall itself stays wet. A negative-side treatment keeps water out of the room, but it won’t keep moisture out of the concrete and it won’t bridge cracks that keep moving, so both are checked before it’s chosen.

Why do negative-side quotes vary?

Mostly the preparation. Running leaks have to be stopped before any coating, and a painted or damaged surface has to be opened up. Compare whether both are in the price, and how many coats go on.

Is negative-side waterproofing as good as tanking from outside?

It isn’t a like-for-like substitute. Outside tanking keeps the wall dry; negative-side keeps the room dry while the wall stays wet. Where the outside can be reached, tanking is usually the better choice; where it can’t, negative-side is the practical one.

Can it go over a painted wall?

No. Paint and old coatings stop the system bonding, so they’re ground off back to the concrete or masonry first.

Will it fix rising damp in an old brick wall?

Rising damp in above-ground brickwork is a different problem, usually dealt with by a damp-proof course. Negative-side systems are for walls holding back soil and water.