NSW contractor licence 260823C
Torch-on waterproofing in Sydney
We lay torch-on membranes: reinforced bitumen sheets heated with a gas torch so they bond to the roof and fuse to each other at every lap.
Finished look- Base and cap sheets
- Every lap welded
- Upstands and outlets detailed
Get a free quote
Torch-on waterproofing
Add photos if you can. We usually reply within one business day.
NSW contractor licence 260823C
Our service
What torch-on work includes
Priming
A bitumen primer on clean, dry concrete so the sheet bonds across its whole area.
Base and cap sheets
Often two layers, with the laps staggered so no join sits over another.
Welded laps
Every side and end lap heated and rolled until a bead of bitumen shows along the edge, the visible sign of a good weld.
Upstands and outlets
Sheets taken up parapets and finished with a termination bar or flashing, and dressed down into the outlets.
Fire precautions
An extinguisher at hand, combustibles cleared from the work area, and the roof checked again after the torch is off.
Signs
Torch-on or something else?
A large, open roof
Few penetrations and long straight runs suit sheets.
Lots of penetrations
Pipes, brackets and plant bases are easier to seal with a liquid membrane, sometimes used with torch-on across the open areas.
Timber or combustibles nearby
Plywood decks, timber framing or foam insulation near the work rule out an open flame, or call for a different system.
Exposed or covered
An exposed roof takes a cap sheet with a mineral surface to shield the bitumen from UV; under pavers, the sheet is covered by a protection layer instead.
The build-up
A two-layer torch-on roof
An exposed torch-on system on a concrete roof slab.
Laps staggered over the base sheet; the granules shield it from UV. At parapets, a termination bar and flashing hold the top edge.
Torched down across the roof, laps fused.
Gives the sheet a surface it can bond to.
Clean, dry and falling to the outlets.
Diagram of a typical job, not to scale. Select a layer to see what it does.
Step by step
How the job runs
- 1
Photos and a quote
Photos of the roof and what’s around it, because an open flame rules torch-on out near timber, cladding or other heat-sensitive materials. We usually reply within one business day.
- 2
Primed and made safe
Clean, dry concrete is primed with bitumen primer, combustibles are cleared and an extinguisher is kept at hand.
- 3
Sheets welded
Base and cap sheets with staggered laps, every lap heated and rolled until a bead of bitumen shows.
- 4
Upstands and a final check
Sheets are finished up parapets and into the outlets, and the roof is checked again after the torch is off.
Prices
How we price torch-on waterproofing
Torch-on is priced on the roof area, one or two layers, the upstands and outlets, and any old membrane to strip, so we price it from photos or a visit. Quotes are free.
What moves the price: our cost guideWhy choose us
Licensed, insured and backed in writing
A licensed waterproofer who does the job once and does it properly, with the insurance, paperwork and warranty to back it.
Check licence 260823C on the NSW registerLicence 260823C
NSW Waterproofing Technician since 2013, current to 10 July 2028.
$20m insured
Public liability cover on every job, big or small.
Statutory warranties
On home building work in NSW: six years for major defects, two for others.
Tested before it’s covered
Showers, bathrooms, balconies and flat roofs flood tested, with a waterproofing certificate.
Before you book
Details and questions
Still not sure?
Send a few photos of the job and the answer comes back with your free written quote.
Send photos for a quoteCall 0451 662 300More about this work
Torch-on is a sheet of polymer-modified bitumen with a reinforcing mat through the middle. The underside is heated with a gas torch until it melts and is rolled onto a primed surface; at each overlap the bitumen of the two sheets fuses into one.
Torch-on suits large flat concrete roofs, roof terraces under pavers and other open areas with few penetrations. The sheet is the same thickness from edge to edge, which is harder to control with a membrane applied by roller. On a roof over rooms it’s an external membrane like any other, so AS 4654.1 and AS 4654.2 apply.
It suits less well where there are many pipes and plinths, small awkward shapes, or anything combustible close by. An open flame on a roof is a fire risk, so the work is planned around timber, insulation and vents, and many buildings require a hot-work permit before it starts.
Why do torch-on quotes differ?
The number of layers and the detail work. Compare whether it’s one sheet or two, whether upstands, outlets and edges are included, and how the roof is made safe for the work.
How long does torch-on last?
It depends on the sheet, whether it’s exposed and how well the roof drains. A cap sheet with its mineral surface intact, on a roof that doesn’t pond, lasts far longer than bare bitumen sitting in water. For a figure, ask for the data sheet of the sheet on your quote.
Is torch-on safe on my building?
It’s safe when the site suits it and the work is planned for it: a concrete substrate, combustibles cleared and no flame near timber eaves, insulation or vents. Where that can’t be done, a liquid or self-adhesive system does the job without a flame.
Can old torch-on be repaired?
Often, yes. A lifted lap or a puncture is cleaned, heated and covered with new sheet welded over it, provided the sheet around it is still sound and bonded.